Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Chim Acta ; 1202: 339654, 2022 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-35341526

RESUMO

Three sets of Carbon Dots (Cdots) were produced through the carbohydrates acid thermal decomposition method. These nanoparticles were functionalized with a polymer, known for its biological compatibility: polyethylene glycol, PEG200, and folic acid, FA, a biomolecule associated with the reactive oxygen and nitrogen (ROS/RNS) savaging process, thus resulting CdotsPEG200, CdotsPEG200FA and CdotsFA. These nanoparticles were tested as nitric oxide radical (NO·) sensors and it was determined that CdotsPEG200FA and CdotsFA fluorescence intensity was quenched by the presence of this radical specie. Moreover, according to the Benesi-Hilderbrand plot, the nanoparticles have a high affinity towards the analyte and this interaction is consistent with a 1:1 stoichiometry, through an independent mechanism. The Stern-Volmer constant, obtained for both sensing systems, is compatible with the formation of stable complexes (static quenching) between the Folic Acid residues on the Cdots surface and NO·. The detection and quantification limits along with the sensitivity were calculated for both nanoparticles: DL (31.7 ± 0.02) x 10-9, QL (96.29 ± 0.01) x 10-9, Sensitivity (5.2 ± 0.5) x 109 M for CdotsFA and DL (83 ± 3) x 10-10, QL (251 ± 2) x 10-10, Sensitivity (8.4 ± 0.3) x 1010 M. These values are adequate for biological sensing and are quite competitive with other reported nanosensors for NO· detection and quantification.


Assuntos
Carbono , Nanopartículas , Carbono/química , Ácido Fólico , Nanopartículas/química , Oxigênio/química , Espécies Reativas de Nitrogênio
2.
Spectrochim Acta A Mol Biomol Spectrosc ; 265: 120380, 2022 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-34562863

RESUMO

The pressing need to develop a specific analytical sensor that can identify and quantify Fe(II) without a cytotoxic response was the major motivation drive in this work. The turn-on fluorescent sensor here described can successfully detect Fe(II) and discriminate this ion from other analytes that commonly act as interferents in biological media. Moreover, this reduced fluoresceinamine-based sensor has a high photostability and high dissociation constant, which is an indication that the complex obtained between reduced fluoresceinamine (RFL) and Fe(II) is highly stable. This fluorescence-based sensor has a binding mechanism of 1:1 and a positive cooperativity was found between analyte and sensor. The detection, quantification and sensitivity parameters of the sensor were determined: 21.6 ± 0.1 µM; 65.6 ± 0.1 µM and 48 ± 3 (×107) µM, respectively. To evaluate a possible cytotoxicity effect an erythrocyte assay was performed and the obtained data were evaluated considering CdTe Quantum Dots (QDs) passivated with mercaptoacetic acid has experimental control. According to the resulting data RFL is not cytotoxic even when used in high concentrations, 660 mM. On the other hand QDs are quite different. Indeed it was proven that these heavy metal-based nanoparticles are responsible for 40% erytrocytes hemolysis in concentrations of 600 mM.


Assuntos
Compostos de Cádmio , Pontos Quânticos , Compostos Ferrosos , Corantes Fluorescentes , Ferro , Pontos Quânticos/toxicidade , Espectrometria de Fluorescência , Telúrio
3.
Small ; 16(28): e1907661, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32462808

RESUMO

Non-Newtonian nanofluids present outstanding features in terms of energy transfer and conductivity with high application in numerous areas. In this work, non-Newtonian nanofluids based on carbon dots (Cdots) functionalized with ionic liquids (ILs) are developed. The nanofluids are produced using a simple, single-step method where the raw materials for the Cdots synthesis are glucose and waste biomass (chitin from crab shells). The use of ILs as both reaction media and functionalization molecules allows for the development of a new class of nanofluids, where the ILs on the Cdots surface represent the base-fluid. Here, the well-known benign IL 1-butyl-3-methylimidazolium chloride ([Bmim]Cl) and a novel home-made IL (1-tosylate-3-methyl-imidazolium triflate) [Tmi][Trif] are used. The nanofluids obtained from both substrates show, apart from high conductivity and viscosity, light absorption, and good wettability, an appealing thermal sensitivity behavior. This thermal sensitivity is preserved even when applied as thin films on glass slides and can be boosted using the surface plasmon resonance effect. The results reported demonstrate that the new Cdots/IL-based nanofluids constitute a versatile and cost-effective route for achieving high-performance thermosensitive non-Newtonian sustainable nanofluids with tremendous potential for the energy coatings sector and heat transfer film systems.


Assuntos
Líquidos Iônicos , Carbono , Condutividade Elétrica , Imidazóis , Viscosidade
4.
J Fluoresc ; 29(2): 343-346, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30887388

RESUMO

In this work, we report a new chemiluminescence system using bis-(2,4,6-trichlorophenyl) oxalate (TCPO) with hydrogen peroxide and luminol as fluorophore. The intense chemiluminescence reaction here described was fully investigated and it was determined that this fluorescent system has two strong light emissions at 440 and 490 nm, respectively. This new, user friendly, intense and striking light emission chemiluminescence system can be used as a very usefull tool for the design and construction of fluorescencent chemical sensors.

5.
Anal Chim Acta ; 735: 90-5, 2012 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-22713921

RESUMO

We report within this paper the development of a fiber-optic based sensor for Hg(II) ions. Fluorescent carbon nanoparticles were synthesized by laser ablation and functionalized with PEG(200) and N-acetyl-L-cysteine so they can be anionic in nature. This characteristic facilitated their deposition by the layer-by-layer assembly method into thin alternating films along with a cationic polyelectrolyte, poly(ethyleneimine). Such films could be immobilized onto the tip of a glass optical fiber, allowing the construction of an optical fluorescence sensor. When immobilized on the fiber-optic tip, the resultant sensor was capable of selectively detecting sub-micromolar concentrations of Hg(II) with an increased sensitivity compared to carbon dot solutions. The fluorescence of the carbon dots was quenched by up to 44% by Hg(II) ions and interference from other metal ions was minimal.


Assuntos
Carbono/química , Cátions Bivalentes/análise , Corantes Fluorescentes/química , Mercúrio/análise , Nanopartículas/química , Fibras Ópticas , Acetilcisteína/química , Nanopartículas/ultraestrutura , Sensibilidade e Especificidade , Espectrometria de Fluorescência/métodos
6.
Environ Sci Technol ; 46(4): 2406-12, 2012 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-22296411

RESUMO

In the last years, a rising trend of pollen allergies in urban areas has been attributed to atmospheric pollution. In this work, we investigated the effects of SO(2) and NO(2) on the protein content, allergenicity, and germination rate of Acer negundo pollen. A novel environmental chamber was assembled to exposure pollen samples with SO(2) or NO(2) at two different levels: just below and two times the atmospheric hour-limit value acceptable for human health protection in Europe. Results showed that protein content was lower in SO(2)-exposed pollen samples and slightly higher in NO(2)-exposed pollen compared to the control sample. No different polypeptide profiles were revealed by SDS-PAGE between exposed and nonexposed pollen, but the immunodetection assays indicated higher IgE recognition by all sera of sensitized patients to Acer negundo pollen extracts in all exposed samples in comparison to the nonexposed samples. A decrease in the germination rate of exposed in contrast to nonexposed pollen was verified, which was more pronounced for NO(2)-exposed samples. Our results indicated that in urban areas, concentrations of SO(2) and NO(2) below the limits established for human protection can indirectly aggravate pollen allergy on predisposed individuals and affect plant reproduction.


Assuntos
Acer , Poluentes Atmosféricos/toxicidade , Dióxido de Nitrogênio/toxicidade , Pólen/efeitos dos fármacos , Dióxido de Enxofre/toxicidade , Acer/fisiologia , Alérgenos/fisiologia , Germinação/efeitos dos fármacos , Humanos , Hipersensibilidade Imediata/sangue , Hipersensibilidade Imediata/imunologia , Imunoglobulina E/sangue , Imunoglobulina E/imunologia , Proteínas de Plantas/metabolismo , Pólen/crescimento & desenvolvimento , Pólen/imunologia
7.
Biosens Bioelectron ; 26(4): 1302-6, 2010 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-20675118

RESUMO

An optical fiber sensor for Hg(II) in aqueous solution based on sol-gel immobilized carbon dots nanoparticles functionalized with PEG(200) and N-acetyl-L-cysteine is described. This sol-gel method generated a thin (about 750 nm), homogenous and smooth (roughness of 2.7±0.7 Å) film that immobilizes the carbon dots and allows reversible sensing of Hg(II) in aqueous solution. A fast (less than 10 s), reversible and stable (the fluorescence intensity measurements oscillate less than 1% after several calibration cycles) sensor system was obtained. The sensor allow the detection of submicron molar concentrations of Hg(II) in aqueous solution. The fluorescence intensity of the immobilized carbon dots is quenched by the presence of Hg(II) with a Stern-Volmer constant (pH=6.8) of 5.3×10(5) M(-1).


Assuntos
Técnicas Biossensoriais/métodos , Carbono , Mercúrio/análise , Fibras Ópticas , Pontos Quânticos , Técnicas Biossensoriais/instrumentação , Fluorescência , Microscopia de Força Atômica , Microscopia Eletrônica de Varredura
8.
Sensors (Basel) ; 10(3): 1661-9, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-22294892

RESUMO

A new fluorescent sensor for nitric oxide (NO) is presented that is based on its reaction with a non fluorescent substance, reduced fluoresceinamine, producing the highly fluorescent fluoresceinamine. Using a portable homemade stabilized light source consisting of 450 nm LED and fiber optics to guide the light, the sensor responds linearly within seconds in the NO concentration range between about 10-750 µM with a limit of detection (LOD) of about 1 µM. The system generated precise intensity readings, with a relative standard deviation of less than 1%. The suitability of the sensor was assessed by monitoring the NO generated by either the nitrous acid decomposition reaction or from a NO-releasing compound. Using relatively high incubation times, the sensor also responds quantitatively to hydrogen peroxide and potassium superoxide, however, using transient signal measurements results in no interfering species.


Assuntos
Técnicas Biossensoriais/métodos , Fluoresceínas/química , Óxido Nítrico/análise , Técnicas Biossensoriais/instrumentação , Tecnologia de Fibra Óptica/instrumentação , Corantes Fluorescentes/química , Hidrazinas/química , Peróxido de Hidrogênio/química , Limite de Detecção , Modelos Lineares , Reprodutibilidade dos Testes , Superóxidos/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...